LIQUIDSPECIFIC GRAVITY*NORMAL BOILING POINT (°F)NORMAL BOILING POINT (°C)
Acetaldehyde0.7836820
Acetate Solvents (typical)0.88160–300 (range)71–149 (range)
Acetic Acid1.051245118
Acetone0.79713356
Acrylonitrile0.80617177
Alcohol, Butyl (n-Butanol)0.81244118
Alcohol, Denatured0.8017278
Ammonia, Anhydrous0.64-28-33
n-Amyl Acetate0.876300149
Aniline1.023364184
Benzene (Benzol)0.87917680
Butadiene0.62124-4
n-Butane0.59931-1
Butene (1-Butene)0.6121-6
n-Butyl Acetate0.882259126
Carbon Dioxide1.057-109 (sublimes)-78.5 (sublimes)
Carbon Tetrachloride (dry)1.58517077
Chloroform1.47414261
Chlorobenzene (Monochlorobenzene)1.107270132
Cyclohexane0.77917781
1,3-Cyclopentadiene0.8010641
Diethylamine0.7113256
1,1-Difluoroethane (R-152a)1.004-12.5-25
Divinylbenzene0.929391199
Ethane0.446-128-89
Ethanolamine (MEA)1.018339171
Ether (Diethyl Ether)0.7149434
Ethyl Acetate0.90117177
Ethyl Chloride0.9215412
Ethylene Dichloride1.25518283
Ethylene Glycol1.115387197
Ethylene Oxide0.8825111
Gas Oil0.86400–700 (range)204–371 (range)
Gasoline0.74100–400 (range)38–204 (range)
Glycerin1.261554 (decomposes)290 (decomposes)
n-Heptane0.68420998
n-Hexane0.65915669
Hydrogen Fluoride (anhydrous)0.9886719
Hydrogen Sulfide (liquefied)0.92-76-60
Isobutylene0.6020-7
Isopentane0.6198228
Isopropyl Ether0.72515568
Jet Fuel (Jet A)0.82300–570 (range)149–299 (range)
Kerosene0.82300–570 (range)149–299 (range)
Methyl Alcohol (Methanol)0.79214864
Methyl Chloride0.92-11-24
Methylene Chloride1.32610440
Methyl Isobutyl Ketone (MIBK)0.80242117
Mineral Spirits0.785300–400 (range)149–204 (range)
Naphtha0.7790–400 (range)32–204 (range)
Nitric Acid (concentrated)1.50218183
p-Nitrochlorobenzene (pumped molten)1.52 (solid)468242
n-Pentane0.6269736
Perchloroethylene (Tetrachloroethylene)1.62250121
Phenol1.071359182
Phosphoric Acid (85%)1.685316158
Polyethylene Glycol (PEG 400)1.128N/A (decomposes)N/A (decomposes)
Propane0.585-44-42
Propylene0.581-54-48
Propylene Oxide0.839334
Stoddard Solvent0.78300–400 (range)149–204 (range)
Styrene0.906293145
Sulfuric Acid (98%)1.84~640 (decomposes)~337 (decomposes)
Toluene (Toluol)0.866231111
Triethylene Glycol1.125545285
Unsymmetrical Dimethylhydrazine (UDMH)0.79114764
Vinyl Acetate0.93416373
Vinyl Chloride0.9127-14
Water, Boiler Feed1.00212100
Water, Deionized1.00212100
Whiskey (80 proof)0.95~180 (varies with proof)~82 (varies with proof)
Xylene (Xylol, mixed isomers)0.87280138

*Specific gravity is approximate and relative to water. Values for liquids that are liquid at room temperature are near 60–68°F (16–20°C); liquefied gases (ammonia, propane, butane, etc.) are listed at or near their normal boiling point. Specific gravity and boiling point change with temperature, pressure, concentration and grade, and ranges shown for fuels and solvents are typical for those blends. Data compiled from published physical-property references and manufacturer SDS data for general reference only. Confirm properties for your specific fluid and operating conditions before selecting equipment.

How to Use Boiling Point and Specific Gravity in Pump Selection

Specific gravity: converting head to pressure and power

A pump develops the same head in feet regardless of the liquid, but the pressure and horsepower it takes depend on specific gravity (SG):

  • Pressure (psi) = Head (ft) × SG ÷ 2.31
  • Brake horsepower = GPM × Head (ft) × SG ÷ (3960 × pump efficiency)

For example, a pump developing 500 ft of head produces about 216 psi on water (SG 1.0) but only about 127 psi on propane (SG 0.585). On 98% sulfuric acid (SG 1.84) the same pump produces about 398 psi and needs 84% more horsepower than on water, so the motor must be sized for the actual liquid.

Boiling point, vapor pressure and NPSH

A liquid’s boiling point is the temperature at which its vapor pressure equals the pressure above it. When a liquid is stored at or near its boiling point (a refrigerated ammonia tank, a pressurized LPG bullet, a deaerator or a condensate receiver), the pressure on the liquid surface is essentially equal to its vapor pressure. That pressure difference then contributes nothing to the Net Positive Suction Head available (NPSHa):

  • NPSHa (ft) = 2.31 × (Surface pressure − Vapor pressure, psia) ÷ SG + Static liquid height above pump − Suction friction loss

In these services NPSHa often comes only from the few feet of liquid above the pump suction. If the pump needs more NPSH than is available, the liquid flashes to vapor at the impeller eye and the pump cavitates, causing noise, vibration, loss of flow and impeller damage.

Example: liquid propane from a storage tank

Propane stored in a pressurized tank is at its vapor pressure, so the pressure term above is zero. With the liquid level 4 ft above the pump suction and 1 ft of suction friction loss, NPSHa is only about 3 ft. A typical centrifugal pump needing 8–10 ft NPSHr would cavitate; a Roth pump that needs only 1 ft NPSHr runs with margin to spare. To check your own application, try our NPSH Calculator.

Need Help Selecting a Pump for Your Liquid?

Roth Pump has been building pumps for low-NPSH, near-boiling and hard-to-handle liquids for decades. Explore the pumps most often used for the liquids in this chart:

Not sure which pump fits your fluid? Send us your liquid, temperature, flow and pressure, and we’ll recommend a pump. Contact Roth Pump, call 1-888-444-ROTH, or find your local Roth representative.