| LIQUID | SPECIFIC GRAVITY* | NORMAL BOILING POINT (°F) | NORMAL BOILING POINT (°C) |
|---|---|---|---|
| Acetaldehyde | 0.783 | 68 | 20 |
| Acetate Solvents (typical) | 0.88 | 160–300 (range) | 71–149 (range) |
| Acetic Acid | 1.051 | 245 | 118 |
| Acetone | 0.797 | 133 | 56 |
| Acrylonitrile | 0.806 | 171 | 77 |
| Alcohol, Butyl (n-Butanol) | 0.81 | 244 | 118 |
| Alcohol, Denatured | 0.80 | 172 | 78 |
| Ammonia, Anhydrous | 0.64 | -28 | -33 |
| n-Amyl Acetate | 0.876 | 300 | 149 |
| Aniline | 1.023 | 364 | 184 |
| Benzene (Benzol) | 0.879 | 176 | 80 |
| Butadiene | 0.621 | 24 | -4 |
| n-Butane | 0.599 | 31 | -1 |
| Butene (1-Butene) | 0.61 | 21 | -6 |
| n-Butyl Acetate | 0.882 | 259 | 126 |
| Carbon Dioxide | 1.057 | -109 (sublimes) | -78.5 (sublimes) |
| Carbon Tetrachloride (dry) | 1.585 | 170 | 77 |
| Chloroform | 1.474 | 142 | 61 |
| Chlorobenzene (Monochlorobenzene) | 1.107 | 270 | 132 |
| Cyclohexane | 0.779 | 177 | 81 |
| 1,3-Cyclopentadiene | 0.80 | 106 | 41 |
| Diethylamine | 0.71 | 132 | 56 |
| 1,1-Difluoroethane (R-152a) | 1.004 | -12.5 | -25 |
| Divinylbenzene | 0.929 | 391 | 199 |
| Ethane | 0.446 | -128 | -89 |
| Ethanolamine (MEA) | 1.018 | 339 | 171 |
| Ether (Diethyl Ether) | 0.714 | 94 | 34 |
| Ethyl Acetate | 0.901 | 171 | 77 |
| Ethyl Chloride | 0.921 | 54 | 12 |
| Ethylene Dichloride | 1.255 | 182 | 83 |
| Ethylene Glycol | 1.115 | 387 | 197 |
| Ethylene Oxide | 0.882 | 51 | 11 |
| Gas Oil | 0.86 | 400–700 (range) | 204–371 (range) |
| Gasoline | 0.74 | 100–400 (range) | 38–204 (range) |
| Glycerin | 1.261 | 554 (decomposes) | 290 (decomposes) |
| n-Heptane | 0.684 | 209 | 98 |
| n-Hexane | 0.659 | 156 | 69 |
| Hydrogen Fluoride (anhydrous) | 0.988 | 67 | 19 |
| Hydrogen Sulfide (liquefied) | 0.92 | -76 | -60 |
| Isobutylene | 0.60 | 20 | -7 |
| Isopentane | 0.619 | 82 | 28 |
| Isopropyl Ether | 0.725 | 155 | 68 |
| Jet Fuel (Jet A) | 0.82 | 300–570 (range) | 149–299 (range) |
| Kerosene | 0.82 | 300–570 (range) | 149–299 (range) |
| Methyl Alcohol (Methanol) | 0.792 | 148 | 64 |
| Methyl Chloride | 0.92 | -11 | -24 |
| Methylene Chloride | 1.326 | 104 | 40 |
| Methyl Isobutyl Ketone (MIBK) | 0.80 | 242 | 117 |
| Mineral Spirits | 0.785 | 300–400 (range) | 149–204 (range) |
| Naphtha | 0.77 | 90–400 (range) | 32–204 (range) |
| Nitric Acid (concentrated) | 1.502 | 181 | 83 |
| p-Nitrochlorobenzene (pumped molten) | 1.52 (solid) | 468 | 242 |
| n-Pentane | 0.626 | 97 | 36 |
| Perchloroethylene (Tetrachloroethylene) | 1.62 | 250 | 121 |
| Phenol | 1.071 | 359 | 182 |
| Phosphoric Acid (85%) | 1.685 | 316 | 158 |
| Polyethylene Glycol (PEG 400) | 1.128 | N/A (decomposes) | N/A (decomposes) |
| Propane | 0.585 | -44 | -42 |
| Propylene | 0.581 | -54 | -48 |
| Propylene Oxide | 0.83 | 93 | 34 |
| Stoddard Solvent | 0.78 | 300–400 (range) | 149–204 (range) |
| Styrene | 0.906 | 293 | 145 |
| Sulfuric Acid (98%) | 1.84 | ~640 (decomposes) | ~337 (decomposes) |
| Toluene (Toluol) | 0.866 | 231 | 111 |
| Triethylene Glycol | 1.125 | 545 | 285 |
| Unsymmetrical Dimethylhydrazine (UDMH) | 0.791 | 147 | 64 |
| Vinyl Acetate | 0.934 | 163 | 73 |
| Vinyl Chloride | 0.912 | 7 | -14 |
| Water, Boiler Feed | 1.00 | 212 | 100 |
| Water, Deionized | 1.00 | 212 | 100 |
| Whiskey (80 proof) | 0.95 | ~180 (varies with proof) | ~82 (varies with proof) |
| Xylene (Xylol, mixed isomers) | 0.87 | 280 | 138 |
*Specific gravity is approximate and relative to water. Values for liquids that are liquid at room temperature are near 60–68°F (16–20°C); liquefied gases (ammonia, propane, butane, etc.) are listed at or near their normal boiling point. Specific gravity and boiling point change with temperature, pressure, concentration and grade, and ranges shown for fuels and solvents are typical for those blends. Data compiled from published physical-property references and manufacturer SDS data for general reference only. Confirm properties for your specific fluid and operating conditions before selecting equipment.
How to Use Boiling Point and Specific Gravity in Pump Selection
Specific gravity: converting head to pressure and power
A pump develops the same head in feet regardless of the liquid, but the pressure and horsepower it takes depend on specific gravity (SG):
- Pressure (psi) = Head (ft) × SG ÷ 2.31
- Brake horsepower = GPM × Head (ft) × SG ÷ (3960 × pump efficiency)
For example, a pump developing 500 ft of head produces about 216 psi on water (SG 1.0) but only about 127 psi on propane (SG 0.585). On 98% sulfuric acid (SG 1.84) the same pump produces about 398 psi and needs 84% more horsepower than on water, so the motor must be sized for the actual liquid.
Boiling point, vapor pressure and NPSH
A liquid’s boiling point is the temperature at which its vapor pressure equals the pressure above it. When a liquid is stored at or near its boiling point (a refrigerated ammonia tank, a pressurized LPG bullet, a deaerator or a condensate receiver), the pressure on the liquid surface is essentially equal to its vapor pressure. That pressure difference then contributes nothing to the Net Positive Suction Head available (NPSHa):
- NPSHa (ft) = 2.31 × (Surface pressure − Vapor pressure, psia) ÷ SG + Static liquid height above pump − Suction friction loss
In these services NPSHa often comes only from the few feet of liquid above the pump suction. If the pump needs more NPSH than is available, the liquid flashes to vapor at the impeller eye and the pump cavitates, causing noise, vibration, loss of flow and impeller damage.
Example: liquid propane from a storage tank
Propane stored in a pressurized tank is at its vapor pressure, so the pressure term above is zero. With the liquid level 4 ft above the pump suction and 1 ft of suction friction loss, NPSHa is only about 3 ft. A typical centrifugal pump needing 8–10 ft NPSHr would cavitate; a Roth pump that needs only 1 ft NPSHr runs with margin to spare. To check your own application, try our NPSH Calculator.
Need Help Selecting a Pump for Your Liquid?
Roth Pump has been building pumps for low-NPSH, near-boiling and hard-to-handle liquids for decades. Explore the pumps most often used for the liquids in this chart:
- Low NPSH Chemical Pumps
- Regenerative Turbine Chemical Process Pumps
- 1 ft NPSH Sealless Magnetic Drive Pumps for hazardous or toxic liquids (see how mag drive pumps handle near-boiling liquids)
- Chemical Multistage Low NPSH Pumps for higher pressures
- Boiler Feed Pumps and Steam Condensate Return Systems for water at or near 212°F
Not sure which pump fits your fluid? Send us your liquid, temperature, flow and pressure, and we’ll recommend a pump. Contact Roth Pump, call 1-888-444-ROTH, or find your local Roth representative.